Kooltech On Twitter Check Out This Marstair Cellar Cooler Installed By Happy Penguin Installation must be carried out in accordance with the marstair installation manual, en 378 and national codes and guidance. 1. installation work on this equipment to be completed by f gas certified technicians who are fully conversant with the appropriate refrigeration and electrical practices and have sound knowledge of. 55908059 01 3h evaporator wiring diagram 3i refrigerant system schematic diagram page 32: system selection process use 2 smaller systems instead of 1 big system. 5 – spares products for spare parts, please ensure the use of official marstair spares. any spare parts taken from other companies, marstair will not be responsible in case of any.
Kooltech On Twitter Check Out This Marstair Cellar Cooler Installed By Happy Penguin Opening hours 8.30am 4.30pm armytage road, brighouse, west yorkshire, hd6 1qf. 01484 405 600 ; sales@marstair. Switch on the system, and run for a few minutes to stabilise. the head pressure should be approximately: r407c: 275 280 psig (18.9 19.6barg) to achieve this remove sealing plug and insert 2mm or 5 64” allen key into setting screw. turn allen key clockwise ( ) or counter clockwise ( ) to readjust the setting. Page 13 wiring diagram 13 18 55908014 19 page 14 14 18 55908014 19 page 15 cxe electronic cooling system controls carel ir33 controller on off switch the switch operates the fan motor and is illuminated when power is supplied to the indoor unit. when switched off, the fan stops, the switch remains illuminated and the crankcase heater in. The popular marstair cellar cooler split system evaporators offer cooling solutions for beer cellars and food preparation areas. choose from our wide range : the well established cxe range for r407c, the cxe low temperature version for more challenging applications, or the value cxea range for r410a. alternatively, the cxe multi split provides.
Marstair Cellar Coolers Cellar Cooling Page 13 wiring diagram 13 18 55908014 19 page 14 14 18 55908014 19 page 15 cxe electronic cooling system controls carel ir33 controller on off switch the switch operates the fan motor and is illuminated when power is supplied to the indoor unit. when switched off, the fan stops, the switch remains illuminated and the crankcase heater in. The popular marstair cellar cooler split system evaporators offer cooling solutions for beer cellars and food preparation areas. choose from our wide range : the well established cxe range for r407c, the cxe low temperature version for more challenging applications, or the value cxea range for r410a. alternatively, the cxe multi split provides. Page 9 3ph fuse size (cooling only systems) fuse note: on 3 ph systems the supply must go to the mcu outdoor unit and then to the cxe indoor unit. for fuse sizing with electric heating contact marstair technical department. wiring diagram master (also shows optional heater) page 10: controller settings. Marstair approximate guide to cellar sizing in m3 at 27°c ambient guide to cooling duty at 8°c and 12.7°c sound pressure levels guide to cxe low temperature at 4°c and 27°c ambient part no. 06617591 15 cellar 8°c cellar 12.7°c system ambient 27°c connections td (kw) sd (kw) shr td (kw) sd (kw) shr suction liquid.
Comments are closed.